DTM-352/332

Model DTM-362, DTM-352, DTM-332
Telescope
Tube Length 158mm/6.22 in.
Magnification 33x (21x/41x with optional eyepieces)
Effective diameter of objective 45mm/1.77 in. (EDM: 50mm/1.97 in.)
Field of view 1°20’
Resolving power 2.5”
Minimum focusing distance 1.3m/4.26 ft.
Distance measurement
Range with Nikon specified prisms  
 Normal conditions (Ordinary haze, visibility approx. 20km/12.5 miles)
  With reflector sheet
  (5 x 5cm)
5 to 100m (16.4 to 328 ft.)
  With mini prism 1,000m/3,280 ft.
  With single prism 2,000m/6,560 ft
  With triple prism 2,600m/8,530 ft.
 Good conditions (No haze, visibility of over 40km/25 miles)
  With reflector sheet
  (5 x 5cm)
5 to 100m (16.4 to 328 ft.)
  With mini prism 1,200m/3,930 ft.
  With single prism 2,300m/7.540 ft.
  With triple prism 3,000m/9,840 ft.
Accuracy (Prism/Precise mode) ±(3+2ppm x D)mm
±(3+3ppm x D)mm (–20°C to –10°C, +40°C to +50°C
Measuring interval*1  
  Precise mode 1.6 sec. (initial 1.6 sec.)
  Normal mode 1.0 sec. (initial 1.4 sec.)
Least count  
 Precise mode 1mm/0.002 ft.
 Normal mode 10mm/0.02 ft.
Ambient temperature
range*2
–20°C to 50°C/–4°F to +122°F
Atmospheric correction  
 Temperature range –40°C to 60°C/–40°F to +140°F
 Barometric pressure 400 to 999mmHg/533 to 1,332hPa/15.8 to 39.3 in.Hg
 Prism offset –999 to 999
Angle measurement  
 Reading system Photoelectric detection by incremental encoder
 Horizontal angle Diametrical(DTM-362/352), Single(DTM-332)
 Vertical angle Single
 Minimum increment
 (Degree, Gon, MIL6400)
Degree: 1/5/10”, Gon: 0.2/1/2mgon, MIL6400: 0.005/0.02/0,05mil
 DIN 18723 accuracy
 (horizontal and vertical)
5”/1.5mgon (3”/1.0mgon:DTM-362)
Tilt sensor  
 Type Dual-axis(DTM-362/352), Single-axis(DTM-332)
 Method Liquid-electric detection
 Compensation range ±3'
 Setting accuracy 1"
Level vial  
 Plate level vial 30"/2mm
 Circular level vial 10'/2mm
Optical plummet  
 Magnification 3x
 Focusing range 0.5m/1.6 ft. to ∞
Display Graphic LCD (128 x 64 dot)
Both sides(DTM-362/352), Single side(DTM-332)
Point memory 10,000 records
Dimensions (W x D x H) 168 x 173 x 335mm/6.6 x 6.8 x 13.2 in.
Weight (approx.)  
 Main unit (with battery) 5.3kg/11.7 lbs.(DTM-362/352),
5.2kg/11.5 lbs.(DTM-332)
 Battery 0.4kg/0.9 lbs
 Carrying case 2.4kg/5.3 lbs
On-board Ni-MH battery
BC-65
 
 Operation time  
  Continuous distance/angle
  measurement
Approx. 16 hours*3
  Distance/angle
  measurement every 30 seconds
Approx. 27 hours
  Angle measurement Approx. 30 hours
Battery charger for BC-80/65 Approx. 2.0 hours for full recharge
Quick charger Q-70C (12V DC cigarette lighter charger) Approx. 2.0 hours (fully discharged BC-65 requires more than one charge)
   
*1 Measuring time may vary depending on measuring distance and conditions.
*2 A special version of the DTM-352 is available that allows operation at extremely low temperatures down to –30 °C.
*3 At 25°C. Operation time may be shorter if battery is not new.
 
 
 