Specifications

  DTM-652 NPL-632
Telescope
Tube length 158mm (6.22ft) 153mm (6.02in)
Image Erect
Effective diameter of objective 45mm/1.77in
(EDM: 50mm/1.97in)
40mm/1.57in
(EDM: 50mm/1.97in)
Magnification 33x (21x/41x w/optional eyepieces) 26x (16x/32x w/optional eyepieces)
Field of view 1°20' 1°30'
Resolving power 2.5" 3"
Minimum focusing distance 1.3m (4.26ft) 1.6m (5.3ft)
Reticle illumination Provided (3 steps)
Distance measurement (with Nikon specified prism)
Under good conditions  
with reflector sheet (5 x 5 cm) 5 to 100m / 16.4 to 328.1ft 1.6 to 300m / 5.3 to 980ft
With mini prism 1100m / 3600ft 1.6 to 3000m / 5.3 to 9800ft
With single prism 2700m / 8900ft 1.6 to 5000m / 5.3 to 16400ft
With triple prism 3600m / 11800ft -
With nine prisms 4400m / 14400ft -
Under normal conditions  
with reflector sheet (5 x 5 cm) 5 to 100m / 16.4 to 328.1ft 1.6 to 300m / 5.3 to 980ft
With mini prism 950m / 3100ft 1.6 to 3000m / 5.3 to 9800ft
With single prism 2400m / 7900ft 1.6 to 5000m / 5.3 to 16400ft
With triple prism 3100m / 10200ft -
With nine prisms 3700m / 12100ft -
Reflectorless mode
(white target)*1
- 1.6 to 210m / 5.3 to 680ft
Readout display 9999.9999m / 29999.999ft
Accuracy
Precise mode ±(2+2ppm x D)mm ±(3+2ppm x D)mm (-10°C to +40°C)
±(3+3ppm x D)mm (–20°C to –10°C, +40°C to +50°C)
Normal mode ±(4+2ppm x D)mm ±(5+10ppm x D)mm
Least count
Precise mode 0.1/1mm, 0.0005ft/0.002ft
Normal mode 1/10mm, 0.002/0.02ft
Measuring intervals (DTM-652)*2
Precise mode 1.0 sec (initial: 1.0 sec) -
Normal mode 0.5 sec (initial:1.0 sec) -
Measuring intervals (NPL-632)*2
Prism mode(Precise mode) - 1.3 sec (initial: 2.0 sec)
Prism mode(Normal mode) - 0.5 sec (initial: 1.6 sec)
Reflectorless (Precise mode) - 1.6 sec (initial: 2.6 sec)
Reflectorless (Normal mode) - 0.8 sec (initial: 2.0 sec)
Ambient temperature range –20°C to 50°C / –4°F to +122°F
Atmospheric correction
Temperature range -40°C to 60°C / -40°F to 140°F
Barometric pressure 400 to 999mmHg/533 to 1,332hPa/15.8 to 39.3 in.Hg
Prism offset correction -999 to +999
Angle measurement
Reading system Photoelectric detection by incremental encoder
(diametrical detection for H/V circles)
Circular diameter 79mm
Minimum increment
(Degree) 0.5"/1"/5" 1"/5"/10"
(Gon) 0.1mgon/0.2mgon/1mgon 0.2mgon/1mgon/2mgon
(MIL6400) 0.002mil/0.005mil/0.02mil 0.005mil/0.02mil/0.05mil
Accuracy 1" / 0.3 mgon 2" / 0.5 mgon
Dual-axis compensator
Method Liquid electric detection, Dual-axis
Compensation range ±3'
Setting accuracy ±1"
Lumi-Guide
Working range 100m / 330ft
Positioning accuracy within approx. 6cm /2.4in at 100m/330ft
Level vials
Sensitivity of plate level vial 30"/2mm
Sensitivity of circular level vial 10'/2mm
Optical plummet
Image Erect
Magnification 3x
Field of view
Focusing range 0.5m /1.6ft to
Display
Type Graphic LCD (128 x 64 dot) on both side
Point memory
Raw/coordinates 10,000 records
External memory device CompactFlash (CF) card, USB memory
Environmental specification IP54
Dimensions(approx.) 166 x 168 x 365mm / 6.5 x 6.6 x 14.4in
Weight
Main unit 5.3 kg / 11.7lbs 5.3 kg / 11.7lbs
BC-80 0.6 kg / 1.3lbs
Operating time DTM-652 Approx. 10 hours
(continuous distance/angle measurement)
Approx. 27 hours
(distance /angle measurement evey 30 seconds)
Approx. 28 hours (angle measurement)
NPL-632 Approx. 6 hours
(continuous distance/angle measurement)
Approx. 12 hours
(distance /angle measurement evey 30 seconds)
Approx. 25 hours (angle measurement)
battery caarger for BC-80/65
Recharging time Approx. 3.0 hours for full recharge
*1: White objects with high reflectivity. Measuring distance may vary depending on targets and measuring conditions.
*2: Measuring distance may vary depending on targets and measuring conditions.
 
Top / Main features / Specifications

 Legal Information
  © Copyright 2006. Nikon-Trimble Co., Ltd.
Home